Subjective assessment of DES using a questionnaire was also conducted at each visit. The TBUT was identified following the procedure reported by Lemp [30]. Everolimus molecular weight A fluorescein strip (Haag-Streit AG, Köniz, Switzerland) was moistened with a drop of saline solution, and placed on the inferior palpebral conjunctiva. The patients were asked to blink several times to mix the fluorescein with the tear film. They were instructed to open their eyes and not blink, and the time between eye opening and the appearance of the first dry spot was measured in seconds. This procedure was repeated three times, and the mean
of the three measurements was recorded finally as TBUT. After the measurement of the TBUT, fluorescein staining on the ocular surface was evaluated using the standardized methods recommended by the National Institutes of Health Symposium on Dry Eye [30]. Briefly, corneal staining was scored 3 minutes after fluorescein instillation by observing the cornea through a cobalt blue light. It was graded using a scale of 0–3 (absent to diffuse) and recorded for the five corneal sections (central, superior, temporal, nasal, and inferior.). The maximum score for each area was 3. The scores of the five areas were summed to obtain a total score for each eye, producing a maximum score of 15. Conjunctival hyperemia
was evaluated by the investigator based on a visual inspection. A standard five-point scoring system was used with the following descriptors based on Histone demethylase photographic
standards: 0 (none) = normal, GSK126 research buy bulbar conjunctival vessels easily observed; +0.5 (trace) = trace flush, reddish-pink color; +1 (mild) = mild flush, reddish color; +2 (moderate) = bright red color; and +3 (severe) = deep, bright, diffuse redness. The Schirmer I test was performed under anesthesia. To obtain anesthetic conditions of all the ocular structures, more than three drops of topical anesthetic (proparacaine hydrochloride ophthalmic solution 0.5%) were applied to the conjunctiva and both lid margins. Then, Schirmer strip was placed on the lower lid 2 mm lateral to the lateral canthus. Patients sat in the dark with both eyes closed for 5 minutes. After the strip was removed, a length of the wet area of the strip was measured in millimeters. The quality and quantity of meibomian gland secretions were evaluated using manual expression. The quantity was graded using a three-point scale: 0 = normal; 1 = delay; 2 = partially blocked; and 3 = blocked. The quality was also scored similarly: 0 = clear; 1 = cloudy; 2 = granular; and 3 = opaque solid. To evaluate subjective symptoms of dry eye, the participants were asked to complete the Ocular Surface Disease Index (OSDI) prior to taking any clinical measurements.